RISCO Group LightSYS 2 User Manual

Page 115

Advertising
background image

Installer Programming

Page 115

Quick Keys

Parameter

Default

Range

ZZ

MW (Microwave) Range   

Trimmer

 

Defines the microwave channel range. 
MINIMUM 25% 50% 65%  85%  MAXIMUM  TRIMMER  
(MW is defined by the trimmer setting on the PCB) 

ZZ

Alarm Logic                  

PIR and Microwave 

 

Determine the detector’s logic of defining an alarm. 
 PIR & MW (and Microwave) – An alarm is activated when both PIR 
and MW channels detect an alarm (AND Logic). 
 PIR / MW (or Microwave) ‐ An alarm is activated when either PIR or 
MW channels detect an alarm (OR Logic). 

ZZ

Lens Type                   

Wide Angle

 

Defines the actual lens of the detector. 
WIDE ANGLE BARRIER / LONG RANGE

ZZ

Anti‐Mask                  

Enable

 

Defines the operation of Anti Masking detection. 
DISABLE ENABLE

ZZ

Arm/Disarm                

No

 

Defines the operation of the LEDs and Anti masking detections while 
the detector is armed. 
 Active IR AM and Proximity AM (Anti masking) is enabled. 
LEDs behave according to the LEDs parameter definition. 
YES – Active IR AM and Proximity AM (Anti masking) is disabled 
LEDs are disabled. 

ZZ

Green Line                 

Yes

 

This feature defines the activation of the microwave channel while the 
system is disarmed. 
NO ‐ Green Line feature is disabled. MW is constantly activated. 
YES ‐ Green Line feature is enabled. This option conforms to 
environmentally friendly standards by avoiding surplus emission. 

ZZ

Sway                           

No

 

This option allows the recognition and immunity of swaying objects in 
a known pattern. 
NO ‐ Sway is disabled. 
YES ‐ Sway is enabled. 

Advertising