RISCO Group LightSYS 2 User Manual

Page 133

Advertising
background image

Installer Programming

Page 133

Quick Keys

Parameter

 

Strobe Trigger 

 

 

 

 

A latched output that is used to trigger a strobe. The output is 
activated when one of the defined partitions is in alarm mode or 
during squawks. The output will be activated until the alarm is 
disarmed. The output is also activated in test mode. 

Note:

A tamper alarm will not activate the output if all the partitions are 
disarmed. 

 

 

Fail To Arm 

 

 

 

 

Activates when one of the defined partitions fails to arm and 
deactivates at user reset.

 

 

Confirm Alarm 

 

 

 

 

The output activates when a confirmed alarm occurs in a partition 
and deactivates at the restore of the alarm confirmation. RISCO 
recommends that you use this output for the Red‐Care STU 
Confirmed Alarm channel. 

 

Duress Follow 

 

 

 

Activates the Utility Output when a DURESS alarm is initiated at the 
keypad related to the selected partition(s).

 

1.

Press 

. The following display appears:  

P=1234 UO=XX
Y...

Note:

The XX in the UO=XX refers to the number of the Utility Output currently being 

programmed

.

2.  Use the 

 key to toggle between Y Yes and N No to designate the partition(s) 

that will activate the selected Utility Output (UO),

 

‐OR‐

 

Press the partition number [1 to 4] to select or deselect it  

3. Press 

  and proceed to Pattern of Operation, page 136 , to set the pattern and 

duration of operation 

Advertising