Installing Bus Devices

Page 40

Setting Bus Accessory ID Numbers

For most devices, a DIP switch number must be set to identify its ID category number.  
Devices are split into ‘Families’. Each ‘Family’ of devices has sequential identification 
numbers which are set by the DIP switches. Before setting power on, define each module’s ID 
number by setting the DIP switches as follows: 

ID

DIP switches

ID

DIP switches

1 2 3

4 5

1 2 3 4 5

01 

OFF 

OFF  OFF  OFF  OFF   

17 

OFF  OFF  OFF  OFF  ON 

02 

ON 

OFF  OFF  OFF  OFF   

18 

ON 

OFF  OFF  OFF  ON 

03 

OFF 

ON 

OFF  OFF  OFF   

19 

OFF  ON 

OFF  OFF  ON 

04 

ON 

ON 

OFF  OFF  OFF   

20 

ON 

ON 

OFF  OFF  ON 

05 

OFF 

OFF  ON 

OFF  OFF   

21 

OFF  OFF  ON 

OFF  ON 

06 

ON 

OFF  ON 

OFF  OFF   

22 

ON 

OFF  ON 

OFF  ON 

07 

OFF 

ON 

ON 

OFF  OFF   

23 

OFF  ON 

ON 

OFF  ON 

08 

ON 

ON 

ON 

OFF  OFF   

24 

ON 

ON 

ON 

OFF  ON 

09 

OFF 

OFF  OFF  ON 

OFF   

25 

OFF  OFF  OFF  ON 

ON 

10 

ON 

OFF  OFF  ON 

OFF   

26 

ON 

OFF  OFF  ON 

ON 

11 

OFF 

ON 

OFF  ON 

OFF   

27 

OFF  ON 

OFF  ON 

ON 

12 

ON 

ON 

OFF  ON 

OFF   

28 

ON 

ON 

OFF  ON 

ON 

13 

OFF 

OFF  ON 

ON 

OFF   

29 

OFF  OFF  ON 

ON 

ON 

14 

ON 

OFF  ON 

ON 

OFF   

30 

ON 

OFF  ON 

ON 

ON 

15 

OFF 

ON 

ON 

ON 

OFF   

31 

OFF  ON 

ON 

ON 

ON 

16 

ON 

ON 

ON 

ON 

OFF   

32 

ON 

ON 

ON 

ON 

ON 

Notes:

Most accessories have four DIP switches, while bus detectors have five DIP switches 

IDs 9–32 are only available for bus detectors. 

If a DIP switch is changed on any device, it is necessary to shut down the device’s 
power and then re‐power it

The first module in each category is defined as ID= 1.  
Families that have sequential ID numbers are: 

Keypads (LCD, LCD with proximity and wireless keypad) 

Zone expanders (8 zones expander, bus zone expander) 

Outputs (4 relay output expander, 8 open collector output expander, 2 relay output 
expander on 4A power supply, 2 relay output expander on Wireless zone expander, 
X‐10 Outputs)  1‐ and 2‐way 

Power supplies (3A switching mode power supply) 

Bus zones           WL zone expanders 

Notes: 

1. The main unit can support a maximum load of 1.4 Amp. If more current

is 

required, install additional power supply modules (3 Amp max.). 

2. On 3 Amp supervised power supplies and on the wireless expander, there are 

two programmable outputs. These programmable outputs belong to the ‘Output’ 
family. These outputs have dedicated DIP switches that identify the OUTPUT ID. 