RISCO Group LightSYS 2 User Manual

Page 128

Advertising
background image

Installer Programming

Page 128

Quick Keys

Parameter

  

Switched Aux 

 

Activates the utility output when a fire zone is activated (for fire 
detection) according to the time defined in double verification of fire 
alarms, page 7777.  

This utility output will not have the option to choose pulse or latch in 
the Utility Output: Code. The pulse time is defined in switched 
auxiliary break, page 71. 

 

  

GSM Error 

 

Relates to GSM/GPRS module. Activates the utility output in the 
following cases: 

There is no SIM card in the GSM/GPRS BUS Module or SIM is 
faulty 

GSM RSSI signal level is low 

GSM network fault 

  

Bell Test 

 

Activates the output when the “Bell Test” option is selected  and 
deactivates when the “Bell Test” option is finished. 

  

Installation 

 

Activates the output following the system installation status. It activates 
when the system is in installer programming mode and deactivates 
when exiting installer’s mode. 

  

Walk Test 

 

Activates the output when the “Walk Test” option is selected and 
deactivates when the “Walk Test” option is finished. 

  

Burglary 

 

Activates the output (Pulsed only) following any intruder activation in 
the system (Regardless the bell time out timer). The maximum number 
of times an output can be activated from the same zone is defined 

according to the Swinger Limit Timer (Quick key  



)  