Installer Programming

Page 141



Installer

Default: 1111 
The Installer Code provides access to the Installer Programming menu, allowing modification 
of all system parameters. The Installer Code is used by the LightSYS2 installation company 
technician to program the system. 
The Installer can change the Installer Code.  



Sub Installer

Default: 2222 
The sub‐installer code allows limited access to selected parameters from the installer 
programming menu. 
We recommend changing the factory default to a code unique to the main panel and/or to 
those who may serve as sub‐installers in your MS, as described in the following procedure. 
The Sub‐Installer is prohibited to access the following parameters: 

 Default Enable 
 Code Length 
 Installer Code 
 Communication menu. 



Code Length

The Code Length specifies the number of digits (either 4 or 6) for the Grand Master and 
Master codes. All the other codes (User, Arm Only and Maid) use from one digit up to a 
maximum of six digits. 

Note:

When you change the code length parameter, all user codes are deleted and must be re‐
programmed or downloaded. 
For a 6‐digit Code Length system, 4‐digit default codes like 1‐2‐3‐4 (Grand Master), 1‐1‐1‐1 
(Installer), and 2‐2‐2‐2 (Sub‐Installer) become 1‐2‐3‐4‐0‐0, 1‐1‐1‐1‐0‐0, and 2‐2‐2‐2‐0‐0, 
respectively. 
If you change the Code Length back to 4 digits, the system codes are restored to the default 4‐
digit codes. 

EN 50131 Note:

 All code length are 4 digits: xxxx 
 For each digit 0‐9 can be used 
 All codes from 0001 to 9999 are acceptable 
 Invalid codes cannot be created since after 4 digits are input, the ʺEnterʺ is automatic. 
 Codes are rejected when trying to create a code that does not exist. 