Mounting and Wiring

Page 28

Notes:

1. The parallel wiring system supports parallel connections from any point along the 

wiring. 

2. The maximum wire run permitted is 300 meters (1000 feet) for all legs of the bus. 
3. In case of bus communication problems, connect two 2.2KΩ resistors, one at each end of 

the data bus terminals, between the green and yellow wires. 

4. If connecting remote power supplies, do NOT connect the Red wire (+12v) between 

the Power Supply Unit and LightSYS2. 

5. For long cable runs, please use the correct cable as stated in Appendix A Technical 

Specifications 

Zone Inputs Wiring

The following diagrams illustrate the various zone connections to the main unit or to 
the 8 wired zones expander and possible 4‐wire smoke detector. 
 

Notes:

1. For a zone with a tamper switch, you can use a double end‐of‐line resistor to save 

additional main panel connections.  

2. It is recommended that you use an end‐of‐line resistor at the far end of each 

hardwired zone (16 x 2.2K resistors are supplied). 

3. In the LightSYS2 you have the ability to define separately the end‐of‐line resistance 

of the zones on the main unit and of the wired zones for each eight‐unit expander 
block (Quick key ). Selection is done by the software with the following 
available options: 

ID

EOL 

DEOL   

ID 

EOL 

DEOL 

Customized 

 

4.7K 

4.7k 

2.2K 

2.2K (Default) 

3.3K 

4.7K 

4.7K 

6.8K 

 

1K 

1K 

6.8K 

2.2K 

 

10 

3.3K 

3.3K 

10K 

10K 

 

11 

5.6K 

5.6K 

3.74K 

6.98K 

 

12 

2.2K 

1.1K 

2.7K 

2.7K 

 

13 

2.2K 

4.7K 

END OF LINE ZONE

(N.O CONTACT)

zone

com

ALARM

2.2

K

DETECTOR

NORMALLY OPEN ZONE

CONFIGURATION

ALARM

zone

com

DETECTOR

NORMALLY CLOSED

ZONE CONFIGURATION

ALARM

zone

com

DETECTOR

END OF LINE ZONE

(N.C CONTACT)

2.2

K

zone

com

ALARM

DETECTOR

DOUBLE END OF LINE

ZONE CONFIGURATION

com

2.2

K

ALARM

TAMPER

zone

2.2

K

DETECTOR