Quick Keys

Parameter

Default

Range



ZZ

 

Key Box

 

 

This zone is mainly used in Scandinavia. Triggering this zone will be 
recorded in the event log. It can also be reported to the monitoring 
station. No alarm is triggered. 
When using this zone you should connect the alarm wiring of this zone 
(usually the auxiliary contact of a door) to an external key box and the 
tamper wiring to the housing switch.  



ZZ

 

KeySwitch Arm 

 

This zone is used by financial institutions such as cash distribution 
centers and banks to control the arming of the vault door or treasury 
department entrance. 
Use this zone for instant arming of the partition in which the zone is 
allocated. This zone cannot perform disarming operation.   



ZZ

 

KeySwitch Delayed Arm 

 

Same as the KeySwitch Arm 

(

ZZ

)

 type but the arming will 

be delayed following exit delayed time.   

 

Sound 

This menu enables you to program the sound produced when a systems 
zone triggers and alarm. Report to the central station are not affected by 
the option of this menu. 

The following sound can be selected:  

Silent: Produces no sound 
Bell Only: Activates the bell sounders for the duration of the Bell 

Timeout period, or until a User Code is entered 

Buzzer Only: Activates each keypadʹs internal piezo buzzer. 
Bell + Buzzer: Activates the bell sounders and the keypadsʹ buzzers 

simultaneously 
Door Chime:  The Door Chime parameter is used as an audible 
sounder to indicate the violation of a zone(s), as follows: 

o

If the system is DISARMED, the systemʹs keypad buzzers make 
three momentary sounds whenever the zone is violated. 

o

If the system is ARMED, only the bell sounders produce the 
alarm. 

A different sound can be defined according to the system status as 
follows 