9–8

Altera Corporation

Stratix GX Transceiver User Guide

January 2005

Recommended Resets

receive_digitalreset,

pll_locked,

rx_freqlocked,

pll_areset,

txdigitalreset,

rxanalogreset,

rxdigitalreset

);

input inclk; //GXB input reference clock

input rx_coreclk;//Receive recovered clock

input sync_reset; //Input: synchronous reset from the system

input async_reset; //Input: async reset from system

input transmit_digitalreset; //Input: Reset only the transmit

digital section

input receive_digitalreset; //Input : Reset the receiver section

input rx_freqlocked; //rx_freqlocked signal from receive;

Transition from 'lock to reference clock mode' to 'lock to data

mode'

input pll_locked; // Transmit PLL of GXB locked

output rxdigitalreset;//GXB Receive digital reset

output rxanalogreset;//Receive power down signal

output txdigitalreset; //GXB transmit digital reset

output pll_areset;//GXB power down signal

reg rxdigitalreset;

wire rxanalogreset;

reg txdigitalreset;

reg pll_areset;

reg [2:0] state;

reg rxdigitalreset_inclk;

reg rxanalogreset_inclk;

reg rxdigitalreset_rx_coreclk_Q;

reg rxanalogreset_rx_coreclk_Q;

parameter IDLE = 3'b000;

parameter STROBE_TXPLL_LOCKED = 3'b001;

parameter STABLE_TX_PLL = 3'b010;

parameter WAIT_STATE = 3'b011;

//Parameter value of T (2ms)based on the fastest clock (or 3.1875

Gbps)

parameter WAITSTATE_TIMER_VALUE = 1000000;

reg [19:0]waitstate_timer; //timer - for actual value, refer

stratix data sheet

assign rxanalogreset = rxanalogreset_inclk;