Altera Stratix GX Transceiver User Manual

Page 100

Advertising
background image

4–18

Altera Corporation

Stratix GX Transceiver User Guide

January 2005

SONET Mode Clocking

One of the clocking interfaces to consider while designing with Stratix GX
devices is the transceiver-to-FPGA interface. This clocking scheme is
further classified as the FPGA-to-transmitter channel and the
FPGA-to-receiver channel to the PLD.

In SONET mode, the read port of the transmitter phase compensation
FIFO module is either clocked by the coreclk_out or by the
tx_coreclk

signal. The constraint on using tx_coreclk is that the

clock must be frequency locked to the read clock of the transmitter phase
compensation FIFO module. Synchronous data transfers for a
multi-transceiver block configuration are accomplished by using the
tx_coreclk

port. The tx_coreclk of multi-transceiver blocks are

connected to a common clock domain either from a single coreclk_out
signal or from an FPGA system clock domain. This scheme is shown in

Figure 4–14

.

Advertising