Reset, Code error detect – Altera Stratix GX Transceiver User Manual

Page 56

Advertising
background image

3–10

Altera Corporation

Stratix GX Transceiver User Guide

January 2005

Basic Mode Receiver Architecture

Figure 3–8. 10-Bit to 8-Bit Conversion

Reset

The rxdigitalreset signal governs the reset condition of the 8B/10B
decoder. In reset, the disparity registers are cleared. Upon exiting reset,
the 8B/10B decoder can start with either a positive or negative disparity.
The decoder calculates the initial running disparity based on the first
valid code received.

The receiver block must be word aligned after reset before the 8B/10B
decoder can decode valid data or control codes.

Code Error Detect

The rx_errdetect signal indicates when the code that is received
contains an error. This port is optional and if not in use, there is no way to
determine whether a code that is received is valid. The rx_errdetect
signal goes high if a code received is an invalid code or if it contains a
disparity error. If a code is received that is not part of the valid Dx.y or
Kx.y list, the rx_errdetect signal goes high. This signal is aligned with
the invalid code word that is received at the device logic array and/or the
code word that triggered the disparity error.

7

6

5

4

3

2

1

0

H

G

F

E

D

C

B

A

8b-10b conversion

7

6

5

4

3

2

1

0

9

8

g

f

i

e

d

c

b

a

j

h

LSB received

first

MSB received

last