Parameter descriptions – Altera Stratix GX Transceiver User Manual

Page 305

Advertising
background image

Altera Corporation

B–9

January 2005

Stratix GX Transceiver User Guide

Parameter
Descriptions

Table B–3

describes the Stratix GX device parameters.

Table B–3. Parameter Descriptions (Part 1 of 6)

Parameter

Type

Required

Comments

OPERATION_MODE

String

Yes

Specifies the operation of the transceiver block
transmitter PLL and transceiver block receiver PLL.
Values are

RX

,

TX

, and

DUPLEX

. If the

PROTOCOL

parameter is set to

XAUI

, then you must set the

OPERATION_MODE

parameter to

DUPLEX

.

LOOPBACK_MODE

String

No

Specifies the operation of the loopback. Values are

NONE

,

SLB

, and

PLB

. If omitted, the default is

NONE

.

Values other than

NONE

are available only when the

OPERATION_MODE

parameter is set to

DUPLEX

.

REVERSE_LOOPBACK

_MODE

String

No

Specifies the operation of the reverse loopback.
Values are

NONE

, and

RSLB

. If omitted, the default is

NONE

. Values other than

NONE

are available only

when the

OPERATION_MODE

parameter is set to

DUPLEX

.

PROTOCOL

String

Yes

Specifies the protocol. Values are

XAUI

,

SONET

,

GigE

, and

Basic

.

NUMBER_OF_CHANNELS

Integer

Yes

Specifies the number of transceiver block receiver or
transmitter channels. Values are

1

through

20

.

NUMBER_OF_QUADS

Integer

Yes

Specifies the number of transceiver blocks.

CHANNEL_WIDTH

Integer

Yes

Specifies the width of the dataout signal from the
transceiver block receiver or transmitter channel atom.
Use the following settings:

For more information, see the table in the comments
for the

DATA_RATE

parameter.

Setting of

PROTOCOL

Parameter

XAUI
SONET
GigE
Basic

Channel Width

Values

16

8

and

16

8

8

,

10

,

16

, and

20

Advertising