Supported Codes

The 8B/10B scheme defines the 12 control codes listed in

Table A–1

for

synchronization, alignment, and general application purposes.

Table A–2

shows the valid data code-groups.

Table A–1. Supported K Codes

K Code

Octal Value

8-Bit Code

HGF_EDCBA

10-Bit Code RD-

abcdei_fghj

10-Bit Code RD+

abcdei_fghj

K28.0

1C

8'b000_11100

10'b001111_0100

10'b110000_1011

K28.1

3C

8'b001_11100

10'b001111_1001

10'b110000_0110

K28.2

5C

8'b010_11100

10'b001111_0101

10'b110000_1010

K28.3

7C

8'b011_11100

10'b001111_0011

10'b110000_1100

K28.4

9C

8'b100_11100

10'b001111_0010

10'b110000_1101

K28.5

(1)

BC

8'b101_11100

10'b001111_1010

10'b110000_0101

K28.6

DC

8'b110_11100

10'b001111_0110

10'b110000_1001

K28.7

FC

8'b111_11100

10'b001111_1000

10'b110000_0111

K23.7

F7

8'b111_10111

10'b111010_1000

10'b000101_0111

K27.7

FB

8'b111_11011

10'b110110_1000

10'b001001_0111

K29.7

FD

8'b111_11101

10'b101110_1000

10'b010001_0111

K30.7

FE

8'b111_11110

10'b011110_1000

10'b100001_0111

Note to

Table A–1

:

(1)

K28.5 is a comma code used for word alignment and indicates an IDLE state.

Table A–2. Valid Data Code-Groups (Part 1 of 9)

Code-group Name

Octet Value

Octet Bits

HGF EDCBA

Current RD-

Current RD+

abcdei fghj

abcdei fghj

D0.0

00

000 00000

100111 0100

011000 1011

D1.0

01

000 00001

011101 0100

100010 1011

D2.0

02

000 00010

101101 0100

010010 1011

D3.0

03

000 00011

110001 1011

110001 0100

D4.0

04

000 00100

110101 0100

001010 1011

D5.0

05

000 00101

101001 1011

101001 0100

D6.0

06

000 00110

011001 1011

011001 0100

D7.0

07

000 00111

111000 1011

000111 0100

D8.0

08

000 01000

111001 0100

000110 1011

Advertising