Wireless cpu, Status commands, At+wind? +wind: 0 ok at+wind=255 – Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual
Page 124: Wind: 1, Wind: 7, Wind: 4

Wireless CPU
®
Status Commands
General Indications +WIND
©Restricted
Page:
118 / 184
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 1
August 23, 2007
<Universal time
and local time
zone>:
indicates date, time and time zone expressed in quarters of an
hour, in format Year/Month/Day,Hour:Min:Seconds±TimeZone
string ("yy/MM/dd,hh:mm:ss±zz")
<LSA Identity>:
localized Service Area identity of the current cell in hexa format
(3 bytes)
hexa string
<Daylight Saving
Time>:
when the local time zone is compensated for DST (Day Saving
time, or summertime), the serving PLMN shall provide a DST
parameter to indicate it. The adjustment for DST can be +1h or
+2h.
range: 0-2
7.1.4
Parameter Storage
The <IndLevel> parameter is stored in EEPROM without using AT&W command. The
default value can be restored using AT&F.
7.1.5
Examples
Command
Responses
AT+WIND?
+WIND: 0
OK
AT+WIND=255
OK
Note: The SIM has been
removed
+WIND: 0
Note: The SIM presence pin has been detected as "SIM removed"
Note: The SIM has been inserted
+WIND: 1
Note: The SIM presence pin has been detected as "SIM inserted"
Note: The network service is available
for an emergency call
+WIND: 7
Note: The initialization has been
completed
+WIND: 4
Note: The Wireless CPU
®
received a
NITZ information message
+WIND: 15,1,"Cingular
Extend",2,"Cingular",3,"+08",4,"03/14/27,1
6:59:48+08",5,"123456",6,"2"