Open AT

®

Commands

Wavecom Open AT

®

Control Command +WOPEN

©Restricted

Page:

44 / 184

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 1

August 23, 2007

Command

Responses

AT+WOPEN=7

+WOPEN: 7,12

OK

Note: Open AT

®

application started on the target.

AT+WOPEN=8

+WOPEN: 8,1,19,24

OK

Note: Safe Boot is active and uses the keys 19 and 24

AT+WOPEN=8,1,10,12

OK

Note: Safe Boot is active and uses the keys 10 and 12.

AT+WOPEN=8,1,10,10

+CME ERROR: 3

Note: Two different keys have to be supplied

AT+WOPEN=8,1,10,16

+CME ERROR: 3

Note: The two supplied keys have to be on the same row or

on the same column

AT+WOPEN=3

+CME ERROR: 532

Note: the embedded application is activated so the flash
objects are not erased

.

AT+WOPEN=4

+CME ERROR: 532

Note: the embedded application is activated so it cannot be

erased

AT+WOPEN=0

Note: Stop the embedded application.

OK

+WIND: 3

Note: Product reset in order to stop the embedded

application.

AT+WOPEN=3

OK

Note: The flash objects are erased

AT+WOPEN=4

OK

Note: The embedded application is erased

AT+WOPEN=6

+WOPEN: 6,768,832

OK

Note: 768 Kbytes are reserved for the A&D storage place,

and 832 for the Open AT

®

application

AT+WOPEN=6,1280

+CME ERROR: 550

Note: The current Open AT

®

application size is too big to

allow this new A&D storage place size.

Advertising