26.12.3 Parameters and Defined Values
<string>:
local ID string
string type
default value: empty string
<nb_characters>:
maximum number of characters
integer type
default value: 20
<ascii_code>:
allowed ASCII code
range: 32-127
26.12.4 Parameter Storage
The <string> parameter is stored in EEPROM using the AT&W command. The default
value can be restored using AT&F.
26.12.5 Examples
Command
Responses
AT+FLID=?
(20),(32-127)
OK
AT+FLID="local ID string"
OK
AT+FLID?
local ID string
OK