17.3.3
Parameters and Defined Values
<fo>:
see note below
<vp>:
validity period
In text mode is only coded in "relative" format.
default value 167 (24 hours)
This means that one byte can describe different values.
0 to 143
(VP + 1) x 5 minutes (up to 12 hours)
144 to 167
12 hours + ( (VP – 143) x 30 minutes )
168 to 196
(VP – 166) x 1 day
197 to 255
(VP – 192) x 1 week
<pid>:
protocol Id (please refer to [1])
string type
<dcs>:
data encoding scheme (please refer to [1])
integer type
Note:
The <fo> byte comprises 6 fields:
b7 b6 b5 b4 b3 b2 b1 b0
RP UDHI
SRR
VPF
RD Mit
RP:
Reply Path, not used in text mode
UDHI:
User Data Header Information
b6=1 if the beginning of the User Data field contains a Header in
addition to the short message. This option is not supported in
+CSMP command, but can be used in PDU mode (+CMGS).
SRR:
Status Report Request.
B5=1 if a status report is requested. This mode is supported.
VPF:
Validity Period Format
b4=0 & b3=0 -> <vp> field is not present
b4=1 & b3=0 -> <vp> field is present in relative format
Others formats (absolute & enhanced) are not supported.
RD:
Reject Duplicates
b2=1 to instruct the SC to reject an SMS-SUBMIT for an SM still
held in the SC which has the same <mr> and the same <da> as