Select Data Compression %C

13.7.1

Description

This command enables or disables data compression negotiation.

13.7.2

Syntax

Action command

AT%C[<n>]

OK

Read command

AT%C?

<n>

OK

Test command
None

13.7.3

Parameters and Defined Values

<n>:

compression mode

0

no compression (default value)

2

V42 compression if supported

13.7.4

Parameter Storage

<n> is stored in EEPROM using the AT&W command. The default value can be