Appendixes – Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual

Page 757

Advertising
background image

APPENDIXES

Technical

Appendixes

© Restricted

Page:

51 / 80

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

APPENDIXES

August 23,

2007

3.2.1.1 Restrictions

• Only basic option and UIH framing is supported.
• Only convergence layers type 1 and 3 are supported.
• Autobauding is not compatible with multiplex mode. It is neither possible to

start multiplexing when autobauding is active (AT+IPR=0), nor to set
autobauding during multiplex mode, since the multiplexer uses only a fixed

baud rate. In the same way, the bit rate can not be changed through AT+IPR

command while multiplex mode is active. Therefore, AT+IPR=<rate> should

not be used, and will have no effect.

Before starting multiplexing mode, port speed must be configured by

AT+IPR=<rate> command, to be compliant with defined values for <port

_speed> parameter (in the volume 1, refer to "Multiplexing Mode +CMUX"

section, "Parameters and Defined Values" section).

3.2.1.2 Specific Behaviors

• In multiplexing mode, AT configuration commands (as AT+CMEE for example),

(see: [2]§ 1.10) will be applied to all logical channels.

• In multiplexing mode, unsolicited result code (see: [2]§ 1.7) will be transmitted

to all logical channels

• AT commands are grouped by classes (SMS, phonebook, GPRS, SIM TOOL

KIT, … See [2] §3.7.1) and launching an AT command from a port, has for the

effect to lock all commands belonging to the same class.

If another port launches an AT command of the locked class, an +CME ERROR:

536 will occur as long as the class is not released (at first command’s

completion time).

• If Bluetooth is started, it is not possible to start CMUX on UART2.

In the same way, it MUX is started on UART2, it is not possible to start

Bluetooth.

• After an at+cfun=1 during a CMUX session, CMUX is automatically restarted

by the Wireless CPU

®

with previous parameters, and all previous opened DLCs

are reopened, with the speed of

at+ipr? Command.

• DCD, RI and DTR signals are managed virtually:

When V24 sets DCD,RI or DTR signal, a MSC frame is sent to remote part, to

indicate a virtual state change .Everything is logical, no physical signals are
involved.

• +++ Escape Sequence is always possible to get offline.
• Flow control is managed physically or virtually by MSC.

By default, the Wireless CPU

®

manage a hardware flow control on a UART, and

this flow control becomes virtual on logical channels when some DLCs are

opened.

At CMUX session stop, Wavecom the Wireless CPU

®

automatically goes back into AT

mode, without having to reset the Wireless CPU

®

.

• Two timeouts are implemented for CMUX connection:

Advertising