Global Configuration Commands

Auto Shutdown: +WASR

©Restricted

Page:

63 / 184

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 1

August 23, 2007

Command

Responses

AT+WASR=2

Note: Get the Auto Shutdown features status

of all UART ports

+WASR:0,1,24,6

OK

Note: There is only one UART port listed because currently

only UART1 supported the Auto Shutdown feature.

AT+WASR=1,1

Note: The Auto Shutdown feature is activated

on UART1 using default GPIO and t1

OK

AT+WASR=2,1

Note: Get the Auto Shutdown feature status of

UART1

+WASR:1,1,24,6

OK

AT+WASR=1

+CME ERROR: 560

Note: Auto Shutdown feature already enabled

AT+WASR=0

Note: The Auto Shutdown feature is

deactivated on all UART ports

OK

AT+WASR=0

+CME ERROR: 560

Note: Auto Shutdown feature already disabled

AT+WASR=1,2

+CME ERROR: 3

Note: <uart> out of range.

AT+WFM=1,”SIM2VONLY”

AT+WHCNF=3,1

AT+CFUN=1

Note: Activate the External SIM Switch feature

AT+WASR=1

Note: Enable Auto Shutdown feature with

current parameters setting

OK

OK

+CME ERROR: 501

Note: GPIO allocation error because External SIM Switch

and Auto Shutdown feature shares the same GPIO.

6.4.6

Notes

After the Auto Shutdown feature is enabled, the users are not allowed to alter the

GPIO, which is dedicated for the Auto Shutdown feature, status by mean of AT

commands (such as +WIOM, +WIOR, +WIOW) or Open AT

®

IO APIs under any

circumstances. If the user tries to change the status (value or direction) of the
dedicated GPIO, an error will be returned.

Once the Auto Shutdown mode is activated on the specified UART (e.g. UART1), no

AT command will be received by the Wireless CPU

®

(as DTR is set to low) through

that UART port. When the Auto Shutdown feature is disabled with AT+WASR

Advertising