PLMN Commands
Read Operator Name +WOPN
©Restricted
Page:
151 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 2
August 23, 2007
Test command
AT+WOPN=?
OK
15.5.3 Parameters and Defined Values
<mode>:
requested operation
0
print operator name using long alphanumeric format
1
print operator name using short alphanumeric format
2
reserved for later use
3
erase NITZ PLMN list if <NumOper>=0
4
read or write the method used for getting PLMN names
read access if <PlmnMethod> omitted.
write access if <PlmnMethod> provided.
<NumOper>:
operator identifier in numeric format (MCC/MNC)
integer type
<AlphaOper>:
operator identifier in long or short alphanumeric format (refer to
section "Operator names" of the Appendixes of the present
document for operator names description)
string type
<lac>:
location Area Code
string type; two byte location area code in hexadecimal format
(e.g. "00C3" equals 195 in decimal)
if it is not entered, current LAC will be used (0 if limited service)
<PlmnOns>:
method for getting PLMN name
bit field (default value: 31)
bit set to 0: method deactivated
bit set to 1: method activated
Bit
0 E-ONS
Bit
1 CPHS
Bit
2 SPN
Bit
3 NITZ
Bit
4 Flash