Battery Commands

Wavecom Battery Charge Management +WBCM

©Restricted

Page:

97 / 158

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 4

August 23, 2007

23.2.4

Parameter Storage

All parameters except <Status> and <BattLevel> are stored in EEPROM without

using the AT&W.command The default value can be restored using AT&F.

23.2.5

Example

Command

Responses

AT+WBCM?

+WBCM: 0,0,4200,3500,100,5000,0,200

OK

Note: Current values (depend on ChargeMode

parameter); in this case, the charging mode is Ni-Cd/Ni-

MH

AT+WBCM=0

Note: Stop the battery charging

OK

AT+WBCM=4,0

Note: Configure the battery charging in Ni-Cd/Ni-

MH mode

OK

AT+WBCM=1,1

Note: Start the battery charging with charge

indications

OK

+WBCI: 2,4060

Note: Unsolicited charge indication: the current battery

voltage is 4.06 V.

AT+WBCM=1,1

Note: Start the battery charging with charge

indications on another port

+CME ERROR: 552

Note: The charge indications are already activated on

another port.

AT+WBCM=1,0

Note: Start the battery charging without charge

indications

OK

AT+WBCM=4,2

Note: Get the charging mode

+WBCM: 4,0

OK

Note: The charging mode is Ni-Cd/Ni-MH