Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual
Page 508

SIM ToolKit Commands
SIM ToolKit Control Response +STCR
©Restricted
Page:
162 / 202
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 3
August 23, 2007
19.6.3
Parameters and Defined Values
<Result>:
SIM response to the operation
0
control response not allowed
1
control response with modification
<Number>:
called number, Service Center Address or SS String
string type (ASCII format)
<MODestAddr>:
MO destination address
string type (ASCII format)
<TextInfo>:
text information
string type (ASCII format)
19.6.4
Parameter Storage
None.
19.6.5
Examples
Command
Responses
+STIN: 9
Note: "Send SMS" proactive command has been sent by
the SIM.
AT+STGI=9
Note: get information about "Send SMS”
+STGI: "Send SM"
+STCR:
1,"+112233445566779","+012345679"
OK
Note: The “Send SMS” was allowed with modifications.
The SC address was changed from +012345679 to
+112233445566779
+STIN: 99
Note: End of session