SIM ToolKit Commands

SIM ToolKit Control Response +STCR

©Restricted

Page:

162 / 202

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 3

August 23, 2007

19.6.3

Parameters and Defined Values

<Result>:

SIM response to the operation

0

control response not allowed

1

control response with modification

<Number>:

called number, Service Center Address or SS String

string type (ASCII format)

<MODestAddr>:

MO destination address

string type (ASCII format)

<TextInfo>:

text information

string type (ASCII format)

19.6.4

Parameter Storage

None.

19.6.5

Examples

Command

Responses

+STIN: 9

Note: "Send SMS" proactive command has been sent by

the SIM.

AT+STGI=9

Note: get information about "Send SMS”

+STGI: "Send SM"

+STCR:
1,"+112233445566779","+012345679"

OK

Note: The “Send SMS” was allowed with modifications.

The SC address was changed from +012345679 to

+112233445566779

+STIN: 99

Note: End of session