Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual

Page 649

Advertising
background image


Battery Commands

Wavecom Autodiag +WDIAG

©Restricted

Page:

101 / 158

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 4

August 23, 2007

23.3.3

Parameters and Defined Values

<type >:

ADC type

0

battery voltage autodiag (default value)

1

ADC auxiliary autodiag

2 Wireless

CPU

®

temperature (Power Amplifier) in mV

(available for Q2687 only)

<mode>:

selfdiagnostic activation mode

0

stop (default value)

1

start

<period>:

period of ADC reading in seconds

0

best effort, approximately 50 readings per second

(default value)

1 - 3600

fixed period in seconds

<trig1>:

minimum threshold

When this threshold is reached, unsolicited response
+WDIAGI is sent to the user application.

0

trigger deactivated (default value)

3200 - 4300

threshold in mV (for <type> = 0)

100 - 2000

threshold in mV (for <type> = 1 or 2)

<trig2>:

maximum threshold

When this threshold is reached, unsolicited response

+WDIAGI is sent to the user application.

0

trigger deactivated (default value)

3200 - 4300

threshold in mV (for <type> = 0)

100 - 2000

threshold in mV (For <type> = 1 or 2)

<trig3>:

delta threshold

When the delta of the last <trig3freq> ADC readings

exceeds the threshold, unsolicited response +WDIAGI is

sent to the user application.

0

trigger deactivated (default value)

10 - 3000

threshold in mV

<trig3_freq>:

number of last values used for the delta calculation

0

5 (default value)

1 10

2 20