Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual

Page 264

Advertising
background image


Data Commands

Other Radio Link Parameters +DOPT

©Restricted

Page:

74 / 156

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 2

August 23, 2007

13.5.3

Parameters and Defined Values

<reset_allowed>:

behaviour in case of bad radio link

0

data communication is hung up in case of bad radio link

1

data communication is held, even if the radio link is bad;

there is a possibility of losing data (default value)

<dtx_allowed>:

power mode

0

normal

mode

1

economic battery mode, not supported by all networks

(default value)

13.5.4

Parameter Storage

Parameters are stored in EEPROM using the AT&W command. The default value can

be restored using AT&F.

13.5.5

Examples

Command

Responses

AT+DOPT=?

(0,1),(0,1)

OK

AT+DOPT=1

OK

Note: Second parameter is omitted

AT+DOPT=1,1

OK

Note: Set new parameters

AT+DOPT?

1,1

OK

AT+DOPT=,0

Note: First parameter is omitted

OK

Advertising