Data Commands
V42 Bis Data Compression Report +DR
©Restricted
Page:
82 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 2
August 23, 2007
13.9.3
Parameters and Defined Values
<status>:
status fo the V42bis use
0
disabled (default value)
1
enabled
<direction>:
DCE-DCE data compression type
NONE
data compression is not in use
V42B
V42bis is in use in both directions
V42B RD
V42bis is in use in receive direction only
V42B TD
V42bis is in use in transmit direction only
13.9.4
Parameter Storage
<status> is stored in EEPROM using the AT&W command. The default value can be
restored using AT&F.
13.9.5
Examples
Command
Responses
AT+DR=?
+DR: (0,1)
OK
AT+DR=1
OK
Note: Reporting enabled
AT+DR?
+DR: 1
OK
ATD0123456789
Note: outgoing data call
+DR: V42B
CONNECT 9600