SIM Commands

Generic SIM Access +CSIM

©Restricted

Page:

128 / 202

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 3

August 23, 2007

returned for the following instructions (See CRSM commands).

· C2 : ENVELOPE

· A2 : SEEK

· A4 : SELECT

Fifth Byte Value Restriction:

For the following instructions (Second Byte):

· A4 : SELECT

· 10 : TERMINAL PROFILE

· C2 : ENVELOPE

· 14 : TERMINAL RESPONSE

· A2 : SEEK

the user must make sure that the value of the fifth Byte of the

instruction corresponds of the length of bytes (data starting

from 6th byte) which follow it.

The value of the Fifth Byte must be equal of the value:

<length>/2 – 5, else the command is not send to the SIM and

"CME ERROR: 3" is returned.

<response>:

Response to the command passed on by the SIM to the MT in

the format as described in 3GPP 11.11 [9] (or 3GPP 51.011 [13])

(hexadecimal character format; refer to CSCS).

hexadecimal type

18.3.4 Parameter Storage
None.

18.3.5 Examples

Command

Responses

AT+CSIM=14,"A0A40000027F20"

Note: Select DF Telecom (7F20)

+CSIM: 4,"9F16"

OK

Note : Command correctly treated with length 16

for response data

AT+CSIM?

OK

AT+CSIM=?

OK