Remote disconnection, Call control commands, 8 remote disconnection – Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual

Page 239

Advertising
background image


Call Control Commands

Remote disconnection

©Restricted

Page:

49 / 156

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 2

August 23, 2007

12.8

Remote disconnection

This message is used by the product to inform the application that an active call has

been released by the remote user.

The product sends "NO CARRIER" to the application and sets the DCD signal.

In addition, for AOC, the product can release the call if credit has expired (release

cause 68 with +CEER command).

Advertising