CMUX start connection: 30 seconds.

After this timeout, MUX is closed, and previous physical port is

reopened.

o

DLC inactivity timeouts: 5 minutes.

This timeout is armed only if no DLC are opened, to avoid to be blocked

into only DLC0 opening channel state. After this timeout, MUX is closed,
and previous physical port is reopened.

3.2.2 Results
AT+CMUX=<mode>[,<subset>[,<port_speed>[,<N1>[,<T1>[,<N2>[,<T2>[,<T3>]]]]]]

], will respond OK when parameters are in the range, and number of parameters are

in correct syntax.
Note: The 230400 (<port_speed> = 6), 460800 (<port_speed> = 7) and 921600

(<port_speed> = 8) speeds are added in AT+CMUX=? and AT+CMUX? responses.

The 230400, 460800 and 921600 speeds are added in AT+IPR=? and AT+IPR?

responses.
AT+CMUX=<mode>[,<subset>[,<port_speed>[,<N1>[,<T1>[,<N2>[,<T2>[,<T3>]]]]]]

], will respond ERROR when:

ERROR Responses

Meaning

+CME ERROR: 3

9

Operation not allowed:

Example: Trying to start a MUX session

during autobauding.

9

Parameters or number of parameters are out

of range.

+CME ERROR: 543

CMUX connection is refused by remote, after a
restart of CMUX protocol by Wireless CPU

®

, due to

a 27.010 connection loss during virtual channels

establishment.

+CME ERROR: 544

CMUX connection Timeout (no answer from the

remote) ie no DLC0 opened response.

+CME ERROR: 545

A CMUX session has been started on a physical
UART, and user tries to start another CMUX

session on other physical UART.

The error,

+CME ERROR: 545 is raised on the

UART where

at+cmux command is trying to be

started again.