<OatState>:

Open AT

®

application current state

returned with <Mode> = 7

This state will be greater than 0 only if the current +WOPEN

command state is 1 (except when OatState = 13, which can

occur even if the application is not started on the target).

0

application is not started (current mode is AT+WOPEN=0)

1

no downloaded application in the Wireless CPU

®

2

bad

checksum

The application binary seems to be corrupted.

3

bad header

The downloaded file seems not to be an Open AT

®

application.

4

version

mismatch

The application binary was built with an SDK version which is

not compatible with the current OS.

5

too many tasks

The number of declared tasks in the application exceeds the

maximum allowed.

6

bad binary init function

The application binary seems to be corrupted.

7

bad task entry point

The application binary seems to be corrupted.

8

link

issue

The application global variables area initialization is

impossible.

9

bad memory configuration

The RAM size required by the application is incorrect.

10

application is not started, starting was cancelled by the Open

AT

®

Safe Boot.

11

reserved

12

application started in target mode

The application is now running on the target.

13

application started in RTE mode

The application is now running in debug mode.