12.13 Single Numbering Scheme +CSNS
12.13.1 Description
This command selects the bearer to be used when an MT single numbering scheme
call is set up (see +CICB).
Note:
Setting the +CSNS command affects the current value of +CICB.
12.13.2 Syntax
Action command
AT+CSNS=<mode>
OK
Read command
AT+CSNS?
+CSNS: <mode>
OK
Test command
AT+CSNS=?
+CSNS: (list of supported <mode>s)
OK
12.13.3 Parameters and Defined Values
<mode>:
bearer to be used
0
voice (default value)
2
fax
4
data
12.13.4 Parameter Storage
The <mode> parameter is stored in EEPROM using AT&W command. The default
value can be restored using AT&F.