Appendixes – Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual

Page 777

Advertising
background image

APPENDIXES

Technical

Appendixes

© Restricted

Page:

71 / 80

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

APPENDIXES

August 23,

2007

3.7.4.1 Sleep on Procedure

In order to place a serial port in Sleep Mode state, the DTE just has to drop its DTR

signal to indicate that it is Busy. Then, Wavecom Wireless CPU

®

(DCE) sets the DTE

CTS low.

1

3

2

DTR (DTE)

Clear to Send

Busy

RX data line (DTE)

Clear to Send

CTS (DTE)

Ready

1: The application drops its DTR to indicate a busy state

2: Wavecom Wireless CPU

®

(DCE) detects DTR drop and check if there are still AT

responses to send on that port.

8 : When DTR is low and there are no more AT response, the DCE sets the

application (DTE) CTS low. (At this point, the associated serial port is in Sleep

Mode state)

Note: While in data mode, the CTS does not follow the DTR.

3.7.4.2 Wake up Procedures

3.7.4.2.1 On DTE initiative: Wake up by DTR Raise

DTR (DTE)

Busy

CTS (DTE)

Not Clear to Send

Clear to Send

Ready

1

2

3

1: The application raises its DTR signal to indicate a ready state (meaning DTE wants

to communicate with the DCE).

2: Wavecom Wireless CPU

®

(DCE) takes into account the DTR signal change. (MSR

IRQ for physical port or protocol frame for CMUX)