Open at, Commands, At+wopen=7 +wopen: 7,0 ok – Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual

Page 49: At+wopen=1 +cme error: 541, At+wopen=2, At+wopen=3 ok, At+wopen=1, Ok +wind: 3

Advertising
background image


Open AT

®

Commands

Wavecom Open AT

®

Control Command +WOPEN

©Restricted

Page:

43 / 184

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 1

August 23, 2007

5.2.4

Parameter storage

The <Mode>, <A&Dsize>, <Key1> and <Key2> parameters are stored in EEPROM

without using the AT&W command. The default value can be restored using AT&F.

5.2.5

Examples

Command

Responses

AT+WOPEN=?

+WOPEN: (0-8),(0-1344),(0-24),(0-24)

OK

AT+WOPEN?

+WOPEN: 0

OK

AT+WOPEN=2

Note: Get the Open AT

®

library versions

+WOPEN: 2,"AT v03.01","AT v02.10"

OK

Note: Open AT

®

version 2.10 application downloaded.

AT+WOPEN=7

+WOPEN: 7,0

OK

Note: Open AT

®

application not started

AT+WOPEN=1

+CME ERROR: 541

Note: since main versions do not match, the Open AT

®

application can not be started.

AT+WOPEN=2

Note: Get the Open AT

®

library versions

+WOPEN: 2,"AT v2.00","AT v2.00"

OK

Note: Open AT

®

v2.00 library version. An embedded

application has been downloaded on this product..

AT+WOPEN=3

OK

Note: The flash objects are erased

AT+WOPEN=1

Note: Start the embedded application.

OK

+WIND: 3

Note: Product resets in order to start the embedded

application.

Advertising