Yaskawa Z1000 AC Drive HVAC User Manual

Page 225

Advertising
background image

HOA Keypad Display

Error

iFEr

Communication Error

Cause

Possible Solutions

A communication error occurred between the drive

and the operator or the USB copy unit.

Check the cable connection.

A non-compatible cable is being used to connect the

USB Copy Unit and the drive.

Use the cable originally packaged with the USB Copy Unit.

HOA Keypad Display

Error

ndAT

Model, Voltage Class, Capacity Mismatch

Cause

Possible Solutions

The drive from which the parameters were copied

and the drive to which the parameters will be written

have different electrical specifications, capacities,

are set to different control modes, or are different

models.

Make sure model numbers and specifications are the same for both drives.

The device being used to write the parameters is

blank and does not have any parameters saved on it.

Make sure all connections are correct, and copy the parameter settings onto the USB Copy Unit or

the operator.

HOA Keypad Display

Error

rdEr

Error Reading Data

Cause

Possible Solutions

Failed while attempting to read parameter settings

from the drive.

Press and hold the READ key on the USB Copy Unit for at least one second to have the unit read

parameters from the drive.

HOA Keypad Display

Task

rEAd

Reading Parameter Settings (flashing)

Cause

Possible Solutions

Displayed while the parameter settings are being

read onto the USB Copy Unit.

This is not an error.

HOA Keypad Display

Error

vAEr

Voltage Class, Capacity Mismatch

Cause

Possible Solutions

The drive from which the parameters were copied

and the drive on which the Verify mode is being

performed have different electrical specifications or

are a different capacity.

Make sure electrical specifications and capacities are the same for both drives.

HOA Keypad Display

Error

vFyE

Parameter settings in the drive and those saved to the copy function are not the same

Cause

Possible Solutions

Indicates that the parameter settings that have been

Read and loaded onto the Copy Unit or HOA Keypad

are different.

To synchronize parameters, either write the parameters saved on the USB Copy Unit or HOA keypad

onto the drive, or Read the parameter settings on the drive onto the USB Copy Unit.

HOA Keypad Display

Task

vrFy

Comparing Parameter Settings (flashing)

Cause

Possible Solutions

The Verify mode has confirmed that parameters

settings on the drive and parameters read to the copy

device are identical.

This is not an error.

5.8 Copy Function Related Displays

YASKAWA ELECTRIC TOEP YAIZ1U 03A YASKAWA AC Drive – Z1000 User Manual

225

5

Troubleshooting

Advertising