No.

(Addr.

Hex)

Name

LCD Display

Description

Analog

Output Level

Unit

U2-07

(86)

Output Voltage at

Previous Fault

Output Voltage

Displays the output voltage at the previous fault.

No signal output

available

0.1 Vac

U2-08

(87)

DC Bus Voltage at

Previous Fault

DC Bus Voltage

Displays the DC bus voltage at the previous fault.

No signal output

available

1 Vdc

U2-09

(88)

Output Power at

Previous Fault

Output kWatts

Displays the output power at the previous fault.

No signal output

available

0.1 kW

U2-11

(8A)

Input Terminal Status at

Previous Fault

Input Term Sts

Displays the input terminal status at the previous fault. Displayed

as in U1-10.

No signal output

available

U2-12

(8B)

Output Terminal Status

at Previous Fault

Output Term Sts

Displays the output status at the previous fault. Displays the same

status displayed in U1-11.

No signal output

available

U2-13

(8C)

Drive Operation Status

at Previous Fault

Inverter Status

Displays the operation status of the drive at the previous fault.

Displays the same status displayed in U1-12.

No signal output

available

U2-14

(8D)

Cumulative Operation

Time at Previous Fault Elapsed time

Displays the cumulative operation time at the previous fault.

No signal output

available

1 h

U2-15

(7E0)

Soft Starter Speed

Reference at Previous

Fault

SFS Output

Displays the speed reference for the soft starter at the previous

fault.

No signal output

available

0.01 Hz

U2-16

(7E1)

Motor q-Axis Current at

Previous Fault

Motor Iq Current

Displays the q-axis current for the motor at the previous fault.

No signal output

available

0.10%

U2-17

(7E2)

Motor d-Axis Current at

Previous Fault

Motor Id Current

OLV/PM

OLV/PM

Displays the d-axis current for the motor at the previous fault.

No signal output

available

0.10%

U2-20

(8E)

Heatsink Temperature at

Previous Fault

Actual Fin Temp

Displays the temperature of the heatsink when the most recent

fault occurred.

No signal output

available

1 °C

U2-30

(3008)

Date Year at Previous

Fault

Date Year YYYY

Displays the year when the most recent fault occurred.

No signal output

available

U2-31

(3009)

Date Month and Day at

Previous Fault

Date Mo Day MMDD Displays the date and day when the most recent fault occurred. No signal output

available

U2-32

(300A)

Time Hours and Minutes

at Previous Fault

Time Hr Min HHMM Displays the time when the most recent fault occurred.

No signal output

available

<1> Display is in the following units: 5A0007 to 5A0017: 0.01 A units; 5A0022 to 5A0242: 0.1 A units.
<2> When reading the value of this monitor via MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current.

u

U3: Fault History

No.

(Addr.

Hex)

Name

LCD Display

Description

Analog

Output Level

Unit

U3-01 to

U3-04

(90 to 93

(800 to

803))

First to 4th Most Recent

Fault

Fault Message 

Displays the first to the fourth most recent faults.

No signal output

available

U3-05 to

U3-10

(804 to

809)

5th to 10th Most Recent

Fault

Fault Message 

Displays the fifth to the tenth most recent faults.

After ten faults, data for the oldest fault is deleted. The most

recent fault appears in U3-01, with the next most recent fault

appearing in U3-02. The data is moved to the next monitor

parameter each time a fault occurs.

No signal output

available

U3-11 to

U3-14

(94 to 97

(80A to

80D))

Cumulative Operation

Time at 1st to 4th Most

Recent Fault

Elapsed Time 

Displays the cumulative operation time when the first to the

fourth most recent faults occurred.

No signal output

available

1 h

U3-15 to

U3-20

(80E to

813)

Cumulative Operation

Time at 5th to 10th Most

Recent Fault

Elapsed Time 

Displays the cumulative operation time when the fifth to the tenth

most recent faults occurred.

No signal output

available

1 h

U3-21

(300B)

Date Year at Most

Recent Fault

Fault 1 YYYY

Displays the year when the most recent fault occurred.

No signal output

available

U3-22

(300C)

Date Month and Day at

Most Recent Fault

Fault 1 MMDD

Displays the date and day when the most recent faults occurred. No signal output

available

B.13 U: Monitors