Flange type models 5a0003 and 5a0004, Flange type exterior and mounting dimensions, Flange type heat loss data – Yaskawa Z1000 AC Drive HVAC User Manual

Page 49

Advertising
background image

2.3 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat

Loss

u

Flange Type Models 5A0003 and 5A0004

n

Flange Type Exterior and Mounting Dimensions

0.08

[2.1]

3.83

[97.2]

2.36

[60.0]

0.44

[11]

10.12 [257.0]

11.81 [300.0]

5.46

[138.8]

0.76

[19.3]

VE

R

TICAL MTG DIM

VE

R

TICAL MTG DIM

5.46

[138.8]

10.24 [260.0]

3.54 [90.0]

1.44 [36.6]

0.44

[11]

1.46

[37]

6.26

[159]

5.28

[134]

5.51

[140.0]

1.45

[37]

7.64

194.0

1.34

[34]

0.8

[20.3]

4.72

[120.0]

FRONT VIEW

HORIZONTAL MTG DIM

HORIZONTAL MTG DIM

0.11

[3]

(6)-MOUNTING

HOLES FOR

#10[M5] SCREWS

0.08

[2]

5.79

[147]

NOTE: Maximum surrounding air temperature is 50 °C [122 °F]

0.2

[5]

Unit: in. [mm]

Figure 2.11 Models 5A0003 and 5A0004

n

Flange Type Heat Loss Data

Drive Model

Voltage Class

Heat Loss (W)

Wt. kg (lb)

(Fc = 2 kHz)

Internal

External

Total

5A0003

600

23.3

21.5

44.8

3.4 (7.5)

5A0004

33.6

27.5

61.1

3.4 (7.5)

2.3 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss