2 standard connection diagram – Yaskawa Z1000 AC Drive HVAC User Manual

Page 71

Advertising
background image

+

-

+

+

for connection options. Never

connect power supply lines to

these terminals

DC link choke

(option)

U

X

+

-

+

+

+

U

X

S

1

S

2

S

3

S

4

S

5

S

6

S

7

A

1

A

2

0 V

AC

R
R
S
S-

IG

Z1000 Drive (600 V)

B

1

1

B

2

2 k

SC

0 V

FM

AM
AC

E (G)

<1>

<2>

<9>

<7>

<8>

<6>

<4>

<3>

+

24 V

+

V

M

1

M

2

Jumper

Braking resistor

(option)

Forward Run / Stop

Reverse Run / Stop

External fault

Fault reset

Multi-speed step 1

Multi-speed step 2

Jog speed

Multi-function

digtial inputs

(default setting)

Sink / Source mode
selection

Factory installed wire link

(default: Sink)

CN5-C

CN5-B

CN5-A

Option board

Shield ground terminal

Multi-function

analog inputs

Power supply +10.5 Vdc, max. 20 mA

Analog Input 1 (Frequency Reference Bias)

0 to +10 Vdc (20 kΩ) Resolution: Unsigned 12 bit

4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)


MEMOBUS/Modbus Communication
RS-422/RS-485 Maximum 115.2 kbps
BACnet Communication
Apogee FLN, Siemens
Metasys N2, Johnson Controls

Termination resistor

(120 , 1/2 W)

DIP

Switch S2

Multi-function relay output (During Run)

250 Vac, max. 1 A

30 Vdc, max 1 A

(min. 5 Vdc, 10 mA)

Multi-function analog output 1
(Output frequency)

-10 to +10 or 0 to +10 Vdc (2 mA)
or 4 to 20 mA

Main Circuit

Control Circuit

shielded line

twisted-pair shielded line

main circuit terminal

control circuit terminal

R/L1
S/L2
T/L3

R
S
T

Main

Switch

Fuse

EMC
Filter

M

3

M

4

Multi-function relay output (Zero Speed)

250 Vac, max. 1 A

30 Vdc, max 1 A

(min. 5 Vdc, 10 mA)

SP

SN

AM

FM

V

I

Off

On

DIP Switch S2

Term. Res. On/Off

Jumper S1
A1/A2 Voltage/Current
Selection

Jumper S5

AM/FM Voltage/Current

Selection

Terminal board

jumpers and switches

FM

<5>

<10>

<9>

Multi-function analog output 2
(Output current)

-10 to +10 or 0 to +10 Vdc (2 mA)
or 4 to 20 mA

Three-Phase
Power Supply
600 V
50/60 Hz

<11>

M

U/T

1

V/T

2

W/T

U

FU
FV
FW

V

W

3

Ground

Cooling fan

M

connectors

Analog Input 2 (Frequency Reference Bias)

0 to +10 Vdc (20 kΩ) Resolution: Unsigned 12 bit

4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)

Fault output

250 Vac, max. 1 A

30 Vdc, max 1 A

(min. 5 Vdc, 10 mA)

MA
MB
MC

V

I

A1 A2

FE

M

5

M

6

Multi-function relay output (Speed Agree 1)

250 Vac, max. 1 A

30 Vdc, max 1 A

(min. 5 Vdc, 10 mA)

External power supply
24 Vdc, max. 150 ma

Terminals , 1, 2, B1, B2 are

+

AM

++

2

+P

SN

+24 Vdc
External
Supply

(max. 150 mA)

+

Figure 3.1 Drive Standard Connection Diagram

<1> Remove the jumper when installing a DC link choke. Models 5A0041 to 5A0242 come with a built-in DC link choke.
<2> Set L8-55 to 0 to disable the protection function of the built-in braking transistor of the drive when using an optional regenerative

converter or dynamic braking option. Leaving L8-55 enabled may cause a braking resistor fault (rF). Additionally, disable Stall
Prevention (L3-04 = 0) when using an optional regenerative converter, regenerative or braking units, or dynamic braking option.
Leaving If L3-04 enabled may prevent the drive from stopping within the specified deceleration time.

<3> Supplying power to the control circuit separately from the main circuit requires 24 V power supply (option).

3.2 Standard Connection Diagram

YASKAWA ELECTRIC TOEP YAIZ1U 03A YASKAWA AC Drive – Z1000 User Manual

71

3

Electrical Installation

Advertising