u

Communication Option Installation Example

Remove the front covers of the drive before installing the option. Communication options can inserted only into the CN5-A

connector located on the drive control board.

Preparing the Drive

1.

Shut off power to the drive, wait the appropriate amount of time for voltage to dissipate, then remove the HOA keypad

(B) and front covers (A, D). Front cover removal varies by model.

DANGER! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply will result in death

or serious injury. Before installing the option, disconnect all power to the drive. The internal capacitor remains charged even after

the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent

electric shock, wait at least five minutes after all indicators are off and measure the DC bus voltage level to confirm safe level.

NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling the option, drive, and

circuit boards. Failure to comply may result in ESD damage to circuitry.

A

B

D

Figure 6.3 Remove the Front Covers and HOA Keypad

2.

With the front covers and HOA keypad removed, apply the LED label (C) in the appropriate position on the drive top

front cover (A).

A

C

NS

MS

TX

RX

Figure 6.4 Apply the LED Label

Connecting Option and Ground Wire

1.

Insert the option (M) into the CN5-A connector (K) located on the drive and fasten it using one of the included screws

(F).

6.4 Option Installation

YASKAWA ELECTRIC TOEP YAIZ1U 03A YASKAWA AC Drive – Z1000 User Manual

241

6

Peripheral Devices & Options

Advertising