6200t total sulfur analyzer introduction, Caution general safety hazard – Teledyne 6200T - Sulfides Analyzer User Manual

Page 25

Advertising
background image

6200T Total Sulfur Analyzer

Introduction

Teledyne Analytical Instruments

25

OPTION

OPTION

NUMBER

DESCRIPTION/NOTES REFERENCE

21

Rack mount brackets only (compatible with carrying strap, Option 29)

N/A

23

Rack mount for external pump pack (no slides)

N/A

Carrying Strap/Handle

Side-mounted strap for hand-carrying analyzer

29

Extends from “flat” position to accommodate hand for carrying.
Recesses to 9mm (3/8”) dimension for storage.
Can be used with rack mount brackets, Option 21.
Cannot be used with rack mount slides.

N/A

CAUTION

General Safety Hazard

A FULLY LOADED 6200T WITH VALVE OPTIONS WEIGHS
ABOUT 18 KG (40 POUNDS).

TO AVOID PERSONAL INJURY WE RECOMMEND THAT TWO
PERSONS LIFT AND CARRY THE ANALYZER. DISCONNECT ALL
CABLES AND TUBING FROM THE ANALYZER BEFORE MOVING
IT.

Analog Inputs

Used for connecting external voltage signals from other instrumentation (such as
meteorological instruments).

64

Also can be used for logging these signals in the analyzer’s internal
DAS

Sections 3.3.1.2
and 6.6

Current Loop Analog
Outputs

Adds isolated, voltage-to-current conversion circuitry to the analyzer’s analog
outputs.

41

Can be configured for any output range between 0 and 20 mA.
May be ordered separately for any of the analog outputs.
Can be installed at the factory or retrofitted in the field.

Sections 3.3.1.4,
5.4.1, 5.9.3, and
5.9.3.5

Parts Kits

Spare parts and expendables

42A

Expendables Kit

includes a recommended set of expendables for

one year of operation of this instrument including replacement sample
particulate filters.

Appendix B

43

Expendables Kit with IZS

includes the items needed to refurbish the

internal zero air scrubber (IZS) that is included.

Appendix B

45

Spare Parts Kit

includes spares parts for one unit.

Appendix B

NO Optical Filter

Recommended for high NOX backgrounds.

47

Required for EN Certification.

N/A

Calibration Valves

Used to control the flow of calibration gases generated from external sources, rather
than manually switching the rear panel pneumatic connections.

50A

Two Teflon® solenoid valve sets located inside the analyzer:
Zero/Span

valve switches between zero air and span gas;

Sample/Cal

valve switches between sample gas and calibration gas.

Sections 3.3.2.3,
3.3.2.4, 9.4, 9.5
and 9.6

Internal Zero/Span (IZS)
Gas Generator

Generates internal zero air and span gas.

51A

Includes heated enclosure for a permeation tube (tube not included –
see SO

2

IZS Permeation Tubes options), an external scrubber for

producing zero air and a set of valves for switching between the
sample gas inlet and the output of the zero/span subsystem,
functionally very similar to the valves included in the zero/span valve
option.

Sections 3.3.2.4,
9.5, 11.3.2 and
12.6.17