Part 1 specification – IAI America REXT User Manual

Page 100

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

78

Part 1 Specification

I/O Signal List

Signal type

Bit

Signal

Description

Details

b15-b7

-

Cannot be used.

-

b6

ST6

Start position command 6

b5

ST5

Start position command 5

b4

ST4

Start position command 4

b3

ST3

Start position command 3

b2

ST2

Start position command 2

b1

ST1

Start position command 1

Command

position

number

b0

ST0

Start position command 0

3.8.2. (20)

b15

BKRL

Forced brake release

3.8.2. (19)

b14-b5

-

Cannot be used.

-

b4

SON

Servo ON command

3.8.2. (5)

b3

RES

Reset command

3.8.2. (4)

b2

STP

Pause command

3.8.2. (2)

3.8.2. (10)

b1

HOME Home return command

3.8.2. (6)

P

LC

o

ut

pu

t

Control

signal

b0

-

Cannot be used.

-

b15-b7

-

Cannot be used.

-

b6

PE6

Current position number signal 6

b5

PE5

Current position number signal 5

b4

PE4

Current position number signal 4

b3

PE3

Current position number signal 3

b2

PE2

Current position number signal 2

b1

PE1

Current position number signal 1

Completed

position

number

b0

PE0

Current position number signal 0

3.8.2. (22)

b15

EMGS Emergency stop

3.8.2. (2)

b14-b13

-

Cannot be used.

-

b12

ZONE1 Zone output 1 monitor

3.8.2. (13)

b11

PZONE Position zone output monitor

3.8.2. (13)

b10-b5

-

Cannot be used.

-

b4

SV

Ready (servo ON)

3.8.2. (5)

b3

ALM

Alarm

3.8.2. (3)

b2

-

Cannot be used.

-

b1

HEND

Home return complete

3.8.2. (6)

PL

C

in

pu

t

Status

signal

b0

PEND

Position complete

3.8.2. (9)

-100-

Advertising