Part 2 startup chapter – IAI America REXT User Manual

Page 272

Advertising
background image

0

Part 2 Startup Chapter

Chapter 2 Mounting and Installation

248

Part 2 Startup Chapter

2.1.3 Interconnecting Multiple Units

(1) Connecting 24-V power supply terminal blocks

Connect the power-supply terminal blocks (24 V, 0 V) of adjacent units using power connection plates, as shown below.

All units other than the Gateway R unit come with power connection plates.

(2) Connecting ROBONET communication connection boards

Connect the adjacent units using ROBONET communication connection boards as shown below. All units other than the

Gateway R unit come with ROBONET communication connection boards.

On the unit installed at the far right, also install the terminal resistor board supplied with the gateway unit.

Power connection plates

ROBONET communication

connection boards

Terminal resistor circuit

board

-272-