Part 3 Maintenance

Chapter 1 T

roubleshooting

368

Part 3 Maintenance

1.3.3 Messages Displayed during Operation Using the Teaching Pendant or PC Software

This section explains the warning messages that may be displayed during operation using the teaching pendant or PC

software.

Code

Message

Description

112

Invalid data

An invalid value was input in a parameter.

(Example) 9601 was input as the serial communication speed by mistake.

Input an appropriate value again.

113

Value too small

The input value is smaller than the setting range.

114

Value too large

The input value is larger than the setting range.

Refer to the actuator specifications or parameter table and input an appropriate value

again.

115

Home return not

completed

The current position was written when home return was not yet completed.

Execute home return again.

117

No movement

data

Target position is not set under the selected position number.

Input the target position first.

11E Unmatched

paired data

The values indicating the magnitude relationship of a pair of data are inappropriate.

(Example) The same value was input in both the parameters for soft limits + and –.

Input appropriate values again.

11F Absolute position

too small

The minimum movement toward the target position is determined by the lead length of the

drive system and resolution of the encoder.

This message indicates that the input target value is smaller than the minimum

movement.

(Example) If the lead length is 20 mm, the encoder’s resolution is 800 pulses and

accordingly the minimum movement becomes 20 y 800 = 0.025 mm/pulse.

In this case, this message will be displayed if 0.02 mm is input as the target

position.

121

Push & hold

search end over

The final position in push & hold operation exceeds the soft limit.

This has no negative effect if the actuator contacts the work part. If the actuator misses

the work part, however, the soft limit will be reached and thus this message is displayed.

Change either the target position or positioning band.

122

Multiple axes

connected at

assignment

An address was assigned when multiple axes were connected.

Assign each address only when one axis is connected.

180

Address change

OK

181

Controller

initialization OK

182

Home change all

clear

183

I/O function

changed

These messages are displayed to confirm operation.

(They do not indicate an operation error or other abnormality.)

202

Emergency stop This message indicates that an emergency stop has been actuated. (It does not indicate

an error.)

20A Servo off during

operation

This message indicates that the servo ON signal (SON) was turned OFF by the PLC while

the actuator was moving, and that the servo turned off and the movement was disabled as

a result.

-400-