Safety Guide

Applicable Modes of IAI’s Industrial Robot

Machines meeting the following conditions are not classified as industrial robots according to Notice of Ministry of Labor No.

51 and Notice of Ministry of Labor/Labor Standards Office Director (Ki-Hatsu No. 340):

(1) Single-axis robo with a motor wattage of 80 W or less

(2) Combined multi-axis robot whose X, Y and Z-axes are 300 mm or shorter and whose rotating part, if any, has the

maximum movement range of within 300 mm

3

including the end of the rotating part

(3) Multi-joint robot whose movable radius and Z-axis are within 300 mm

Among the products featured in our catalogs, the following models are classified as industrial robots:

1. Single-axis ROBO Cylinders

RCS2/RCS2CR-SS8† whose stroke exceeds 300 mm

2. Single-axis robots

The following models whose stroke exceeds 300 mm and whose motor capacity also exceeds 80 W:

ISA/ISPA, ISDA/ISPDA, ISWA/ISPWA, IF, FS, NS

3. Linear servo actuators

All models whose stroke exceeds 300 mm

4. Cartesian robos

Any robot that uses at least one axis corresponding to one of the models specified in 1 to 3

5. IX SCARA robots

All models whose arm length exceeds 300 mm

(All models excluding IX-NNN1205/1505/1805/2515, NNW2515 and NNC1205/1505/1805/2515)

No.

Operation

Description

Description

(2) Cable Wiring

Ɣ Use our company’s genuine cables for connecting between the actuator

and controller, and for the teaching tool.

Ɣ Do not scratch on the cable. Do not bend it forcibly. Do not pull it. Do not

coil it around. Do not insert it. Do not put any heavy thing on it. Failure to

do so may cause a fire, electric shock or malfunction due to leakage or

continuity error.

Ɣ Perform the wiring for the product, after turning OFF the power to the unit,

so that there is no wiring error.

Ɣ When the direct current power (+24V) is connected, take the great care of

the directions of positive and negative poles. If the connection direction is

not correct, it might cause a fire, product breakdown or malfunction.

Ɣ Connect the cable connector securely so that there is no disconnection or

looseness. Failure to do so may cause a fire, electric shock or malfunction

of the product.

Ɣ Never cut and/or reconnect the cables supplied with the product for the

purpose of extending or shortening the cable length. Failure to do so may

cause the product to malfunction or cause fire.

4

Installation

and Start

(3) Grounding

Ɣ The grounding operation should be performed to prevent an electric shock

or electrostatic charge, enhance the noise-resistance ability and control

the unnecessary electromagnetic radiation.

Ɣ For the ground terminal on the AC power cable of the controller and the

grounding plate in the control panel, make sure to use a twisted pair cable

with wire thickness 0.5mm

2

(AWG20 or equivalent) or more for grounding

work. For security grounding, it is necessary to select an appropriate wire

thickness suitable for the load. Perform wiring that satisfies the

specifications (electrical equipment technical standards).

Ɣ Perform Class D Grounding (former Class 3 Grounding with ground

resistance 100: or below).