Part 1 specification, 4) home return operation – IAI America REXT User Manual

Page 243

Advertising
background image



Part 1 Specification

Chapter 4 Controller Unit

219

Part 1 Specification

(4) Home Return Operation

ڦ

330q-rotation Specification

[1] Start of home return o [2] Detection of a mechanical stopper o [3] Reversing o [4] Movement by the offset

o

[5] Home position

ڦ

Multi-rotational Specification

[1] Start of home return o [2] Detection of a home sensor signal (Contact B: Leading edge of the signal or detection of

the signal ON status) o [3] Reversing o [4] Detection of a home sensor signal (Contact B: Leading edge of the signal

or detection of the signal OFF status) o [5] Movement by the offset o [5] Home position

* If home return operation is started within the home sensor detection range, the actuator will move out of the home

sensor detection range and then perform home return operation.

[1]

[2]

[3]

[4]

[5]

Operation range (330q)

Home

(end of rotation in

forward direction)

Offset

Mechanical stopper

Rotational axis

330q-rotation specification RTB/RTC

Home return

[1]

[2]

[3]

[4]

[5]

Home

(end of rotation in

forward direction)

Offset

Home sensor position

Home sensor detection range

Rotational axis

Multi-rotational specification RTBL/RTCL

-243-