5.4.2 Address Correlation Diagram for DeviceNet System (Example)

Master station (station number 63)

Gateway R unit (RGW-DV) (station number 0)

PLC address

(channel number)

Gateway register (PLC output)

Upper byte Lower byte

Corresponding channel

(node address)

Refreshed

automatically.

Refreshed

automatically.

Gateway control signal 0

Gateway control signal 1

Request command

Data 0

Data 1

Data 2

Data 3

(Cannot be used)

(Axis 0) Position data specification (L)

(Axis 0) Position data specification (H)

(Axis 0) Position number

(Axis 0) Control signal

(Axis 1) Position data specification (L)

(Axis 1) Position data specification (H)

(Axis 1) Positioning band specification (L)

(Axis 1) Positioning band specification (H)

(Axis 1) Speed specification

(Axis 1) Acceleration/deceleration spec.

(Axis 1) Push current limiting value

(Axis 1) Control signal

(Axis 0) Current position data (L)

(Axis 0) Current position data (H)

(Axis 0) Completed position number

(Axis 0) Status signal

(Axis 1) Current position data (L)

(Axis 1) Current position data (H)

(Axis 1) Current ampere value (L)

(Axis 1) Current ampere value (H)

(Axis 1) Current speed data

(Cannot be used)

(Axis 1) Alarm

(Axis 1) Status signal

PLC address

(channel number)

Gateway register (PLC input)

Upper byte Lower byte

Corresponding channel

(node address)

Gateway status signal 0

Gateway status signal 1

Response command

Data 0

Data 1

Data 2

Data 3

(Cannot be used)