Part 1 specification, Caution – IAI America REXT User Manual

Page 242

Advertising
background image

0

Part 1 Specification

Chapter 4 Controller Unit

218

Part 1 Specification

4.5 Notes on ROBO Rotary

(1) Home Return Direction

The moving end of the output axis in counterclockwise direction becomes the home position.

Actuators of multi-rotational specification can be ordered with their rotating direction reversed. On these reverse rotation

models, the home return direction corresponds to the clockwise direction.

Caution

If the home return direction of the delivered actuator is changed by a parameter, the home return direction will be

reversed, but the home position will deviate due to the structure of the actuator.

Do not change the home return direction parameter.

(2) Operation (Position Setting) Range

The position value is determined by the angle of movement from the home position.
„

330q-rotation Specification: The position specification range is 0 to 330q.

„

Multi-rotational Specification: The position specification range is as follows.

Mode

Absolute position specification

Relative position specification

Rotational axis, normal mode

-0.15 to +9999.15

-9999.30 to +9999.30

Rotational axis, index mode

0 to 359.99

-360.00 to +360.00

(3) Angular Velocity and Acceleration/Deceleration Command

The rotational angle command is based on angular velocity (deg/sec).

In programs, acceleration/deceleration is specified in “G.”

Rated angular acceleration/deceleration: 0.3 G = 2940 deg/sec.

-242-

Advertising