Part 1 Specification

3.4.5 RS485 SIO

Two modes are available: the Modbus gateway mode in which the unit operates as a Modbus/RTU slave station, and the SIO through
mode in which the unit operates by means of serial communication per the Modbus/RTU and ASCII protocols.

Item

Specification

Modbus gate way mode

SIO through mode

Power supply

Current consumption

600 m A max.

H

o

s

t

R

S

4

8

5

s

p

e

c

if

ic

a

ti

o

n

s

Communication format

1:1 communication connection

conforming to RS485

1:N (1

≤N ≤16) communication

connection conforming to RS485

Communication method

Asynchronous half-duplex

Communication mode

Modbus/RTU

Modbus /RTU, ASCII

Baud rate [bps] *2

9600

19200

38400

57600

115200

230400

38400

57600

115200

230400

Frame delay time

t3.5

Fixed to 1.75 ms

t3.5

Fixed to 1.75 ms

Slave address

Fixed to 63 (3FH)

Axis n umber + 1 (01H to 10H)

Master

ROBON ET

F 600H to F647H

Register address

Arbitrary

ROBON ET
Master

F 700H to F747H

Read Holding Register (03H)

01H to 07H

Available function codes

Preset Single Register (06H)

0FH, 10 H, 11H, 17H

Preset Multiple Register (10H)

Maximum send/receive buffer size

160 byte

Bit length

8 bits

Start bit

1 bit

Stop bit

1 bit

Parity

None

Cable length

1000 m max. (master

RGW- SIO)

SIO

c

o

m

m

u

n

ic

a

ti

o

n

s

p

e

c

ifi

c

a

ti

o

n

s

Transmission path configuration

IAI’s dedicated multi-drop differential communication

Communication method

Half-duplex

Synchronization method

Start-stop method

Transmission path format

Conforming to EIA RS485, 2-wire type

Baud rate

230.4 k [bps]

Error control method

No parity bit, CRC *2

Communication cable

ROBONET communication connection circuit board (supplied), ROBONET

extension cable (when an extension unit is used)

Number of units that can be connected

16 axes max.

En

v

iro

n

m

e

n

t

c

o

n

d

iti

o

n

s

Ambient operating temperature

0 to 40

˚C

Ambient operating humidity

95% RH max. (non-condensing)

Operating ambience

Free from

corrosive gases, flammable gases, oil mist or powder dust.

Storage temperature

-

Storage humidity

95% RH max. (non-condensing)

Vibration resistance

XYZ directions:

10 to 57 Hz, half amplitude

– 0.0 35 mm (continuous) / 0.075 mm

(intermittent)

57 to 150 Hz

– 4.9 m/s

2

(continuous) / 9.8 m/s

2

(intermittent)

Impact resistance

XYZ directions:

147 mm/s

2

, 11 ms, half-sine wav e pulse

Protection degree

I P20

Weight

Approx. 140 g

External dimensions [m m]

34 W x 105 H x 73.3 D [mm]

*1: The baud rate is set by the gateway parameter selection tool.
*2: If the host is a PLC, the PLC must have a RS485 or RS232C interface. If a RS232C interface is used, a
SIO converter (RCB-TU-SIO*) is required.

P

art
1

S

pecif
icati
on

C

h

ap

ter
3

G

atew

ay
R

u

n

it

-43-

Advertising
This manual is related to the following products: