Part 1 specification, 3 protocol format – IAI America REXT User Manual

Page 147

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

123

Part 1 Specification

3.9.3 Protocol Format

3.9.3.1 Gateway Address Map

The slave address is fixed to “63 (3FH)” for the RS485 SIO gateway.

As for gateway registers, inputs (PLC Ÿ ROBONET) are assigned to word addresses F600 H onward in the PLC, while

outputs (ROBONET Ÿ PLC) are assigned to word addresses F700 H onward in the PLC.

These word addresses are the register addresses used in communication messages.

Take note that these addresses vary depending on the gateway parameter settings (assignment of each axis). The address

map on the next page assumes that 12 axes of positioner mode or simple direct mode and two axes of direct numerical

specification mode are connected.

In the sample protocol format explained in this section, axis (0) is operated in the positioner mode, while axis (1) is operated in

the direct numerical specification mode. The gateway address map is as follows.

PLC output Ÿ ROBONET

ROBONETŸ PLC input

Register

address

Upper byte

Lower byte

Upper byte

Lower byte

Register

address

F600

Gateway control signal 0

Gateway status signal 0

F700

F601

Gateway control signal 1

Gateway status signal 1

F701

F602

Request command

Response command

F702

F603

Data 0

Data 0

F703

F604

Data 1

Data 1

F704

F605

Data 2

Data 2

F705

F606

Data 3

Data 3

F706

F607

Cannot be used.

Cannot be used.

F707

F608

(Axis 0) Position data specification (L)

(Axis 0) Current position data (L)

F708

F609

(Axis 0) Position data specification (H)

(Axis 0) Current position data (H)

F709

F60A

(Axis 0) Command position number

(Axis 0) Completed position number

F70A

F60B

(Axis 0) Control signal

(Axis 0) Status signal

F70B

F60C

(Axis 1) Position data specification (L)

(Axis 1) Current position data (L)

F70C

F60D

(Axis 1) Position data specification (H)

(Axis 1) Current position data (H)

F70D

F60E

(Axis 1) Positioning band specification (L)

(Axis 1) Current electrical current (L)

F70E

F60F

(Axis 1) Positioning band specification (H)

(Axis 1) Current electrical current (H)

F70F

F610

(Axis 1) Speed specification

(Axis 1) Current speed data

F710

F611

(Axis 1) Acceleration/deceleration specification

(Reserved)

F711

F612

(Axis 1) Push-current limiting value

Axis (1) Alarm

F712

F613

(Axis1) Control signal

(Axis 1) Status signal

F713

-147-