Part 2 Startup Chapter

Chapter 2 Mounting and Installation

262

Part 2 Startup Chapter

(2) An emergency stop circuit for normal layout when external SIO link is used is shown below.

[1]

[3]

[1]

[2]

[3]

EMG connector

TP connector

Teaching pendant

Gateway R unit

Axis controller unit

ROBONET Communication Connector

Drive-source cutoff signal

(CPU control signal)

Motor drive source

Drive-source cutoff relay

Power-supply input terminal block

Internal power supply common

GND

Emergency

stop reset Emergency stop

TP connection

detection circuit

Axis controller unit

Motor drive source

Drive-source cutoff relay

red

black

yellow

(orange)
(gray)

Controller connection

cable

Control power

e-CON connector

Motor drive power

Motor

Motor

[2]

Extension unit

-286-