Part 1 specification – IAI America REXT User Manual

Page 132

Advertising
background image

0

Part 1 Specification

Chapter 3 Gateway R unit

108

Part 1 Specification

[4] When the push direction is set incorrectly

If the push direction is set incorrectly, the actuator position will deviate by “positioning band x 2,” as shown below.

Exercise caution.

[5] When the return operation after push is specified in relative coordinates

Take note that when relative coordinate

specification is used, the reference

position is not the current position at

which the actuator is stopped after

completing the push operation, but the

target position under the position number

based on which the push operation was

executed.

In this example, setting the position

number as -40 mm in relative coordinates

will cause the actuator to move to the

position at 240 mm (280 – 40).

If the push mode is specified, the actuator

will execute an incremental move from the

stopped position.

Speed

Travel

distance

Actual operation

Intended operation

Actual position reached

(load missed)

Target position

Positioning band Positioning band Positioning band

Speed

Return

operation

Position at which push

operation is completed

(Target position)

-132-