Example of Overall Profibus Address Configuration (positioner 2 mode and solenoid valve modes 1 and 2)

An example of connecting 16 axes in the positioner 2 mode or solenoid valve mode 1 or 2 is shown below.

PLC output Ÿ ROBONET

ROBONETŸ PLC input

Relative

channel*

Upper byte

Lower byte

Upper byte

Lower byte

0

Gateway control signal 0

Gateway status signal 0

2

Gateway control signal 1

Gateway status signal 1

4

Request command

Response command

6

Data 0

Data 0

8

Data 1

Data 1

10

Data 2

Data 2

12

Data 3

Data 3

14

(Cannot be used)

(Cannot be used)

8-word

fixed area

16

(Axis 0) Command position number

(Axis 0) Completed position number

18

(Axis 0) Control signal

(Axis 0) Status signal

20

(Axis 1) Command position number

(Axis 1) Completed position number

22

(Axis 1) Control signal

(Axis 1) Status signal

2 words

24

(Axis 2) Command position number

(Axis 2) Completed position number

26

(Axis 2) Control signal

(Axis 2) Status signal

28

(Axis 3) Command position number

(Axis 3) Completed position number

30

(Axis 3) Control signal

(Axis 3) Status signal

32

(Axis 4) Command position number

(Axis 4) Completed position number

34

(Axis 4) Control signal

(Axis 4) Status signal

36

(Axis 5) Command position number

(Axis 5) Completed position number

38

(Axis 5) Control signal

(Axis 5) Status signal

40

(Axis 6) Command position number

(Axis 6) Completed position number

42

(Axis 6) Control signal

(Axis 6) Status signal

44

(Axis 7) Command position number

(Axis 7) Completed position number

46

(Axis 7) Control signal

(Axis 7) Status signal

48

(Axis 8) Command position number

(Axis 8) Completed position number

50

(Axis 8) Control signal

(Axis 8) Status signal

52

(Axis 9) Command position number

(Axis 9) Completed position number

54

(Axis 9) Control signal

(Axis 9) Status signal

56

(Axis 10) Command position number

(Axis 10) Completed position number

58

(Axis 10) Control signal

(Axis 10) Status signal

60

(Axis 11) Command position number

(Axis 11) Completed position number

62

(Axis 11) Control signal

(Axis 11) Status signal

64

(Axis 12) Command position number

(Axis 12) Completed position number

66

(Axis 12) Control signal

(Axis 12) Status signal

68

(Axis 13) Command position number

(Axis 13) Completed position number

70

(Axis 13) Control signal

(Axis 13) Status signal

72

(Axis 14) Command position number

(Axis 14) Completed position number

74

(Axis 14) Control signal

(Axis 14) Status signal

76

(Axis 15) Command position number

(Axis 15) Completed position number

78

(Axis 15) Control signal

(Axis 15) Status signal

* The relative byte indicates the relative byte address from the beginning of the gateway.